{"id":30177,"date":"2025-04-28T17:17:16","date_gmt":"2025-04-28T15:17:16","guid":{"rendered":"https:\/\/crinspection.it\/2025\/04\/28\/magnetoscopy-how-it-works-and-what-it-is-used-for\/"},"modified":"2026-07-29T10:01:51","modified_gmt":"2026-07-29T08:01:51","slug":"magnetoscopy-how-it-works-and-what-it-is-used-for","status":"publish","type":"post","link":"https:\/\/crinspection.it\/en\/2025\/04\/28\/magnetoscopy-how-it-works-and-what-it-is-used-for\/","title":{"rendered":"Magnetoscopy: how it works and what it is used for"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;10px|||||&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p style=\"font-weight: 400;\"><strong>Magnetoscopy<\/strong>, also known <strong>as magnetic particle testing (MT),<\/strong> is a non-destructive testing (NDT) method used to <strong>detect surface and sub-surface discontinuities in ferromagnetic materials<\/strong>. This method takes advantage <strong>of the magnetic properties of materials<\/strong> to identify <strong>defects<\/strong> such as <strong>cracks<\/strong>, <strong>inclusions<\/strong>, <strong>porosity<\/strong>, and other <strong>discontinuities<\/strong> that could <strong>compromise<\/strong> the <strong>structural integrity<\/strong> of a component. <\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>How magnetic oscopy works<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;Montserrat||||||||&#8221; custom_margin=&#8221;||25px|||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p style=\"font-weight: 400;\">The working principle of magnetoscopy is based on the <strong>application<\/strong> of a <strong>magnetic field<\/strong> to the component to be examined. When the magnetic field encounters a <strong>discontinuity<\/strong>, the magnetic flux lines are distorted, creating a <strong>stray field<\/strong>. By applying <strong>ferromagnetic particles<\/strong> (in dry powder or liquid suspension) to the surface of the component, they are <strong>attracted to the stray field<\/strong> and <strong>accumulate<\/strong> at the <strong>discontinuity<\/strong>, <strong>making it visible<\/strong>.  <\/p>\n<ul><\/ul>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Phases of the magnetoscopy process<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p style=\"font-weight: 400;\">The process of <strong>magnetoscopy<\/strong> is divided into <strong>several phases<\/strong>:<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p style=\"font-weight: 400;\">\u2022 <strong>Surface preparation<\/strong>: The surface of the component must be clean and free of contaminants that could interfere with the magnetization process.<br \/>\u2022 <strong>Magnetization<\/strong>: the component is subjected to a magnetic field using different techniques, such as the application of electric current or the use of permanent magnets or electromagnets.<br \/>\u2022 <strong>Detector application<\/strong>: ferromagnetic particles are applied to the magnetized surface, either dry or in liquid suspension.<br \/>\u2022 <strong>Inspection<\/strong>: The operator examines the surface of the component for any indications of discontinuity, which appear as accumulations of ferromagnetic particles.<br \/>\u2022 <strong>Demagnetization (if necessary):<\/strong> In some cases, it is necessary to demagnetize the component to remove residual magnetism.<br \/>\u2022 <strong>Final cleaning<\/strong>: the component is cleaned to remove residual ferromagnetic particles.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Advantages of magnetic magnetoscopy<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p style=\"font-weight: 400;\">Magnetic tape recording offers several advantages over other NDT methods:<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p style=\"font-weight: 400;\">\u2022 It is a relatively <strong>simple and quick<\/strong> method.<br \/>\u2022 It can detect <strong>surface and sub-surface discontinuities<\/strong>.<br \/>\u2022 It is applicable to a <strong>wide range of ferromagnetic materials<\/strong>.<br \/>\u2022 It is a <strong>cost-effective and portable<\/strong> method.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Applications of Magnetic Scopy<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p style=\"font-weight: 400;\"><strong>Magnetic magnetoscopy<\/strong> is widely used in <strong>several industries<\/strong>, including:<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p style=\"font-weight: 400;\">\u2022 <strong>Aerospace<\/strong>: for the inspection of critical components such as engines and wing structures.<br \/>\u2022 <strong>Automotive<\/strong>: For inspecting engine components, suspensions, and transmission systems.<br \/>\u2022 <strong>Oil and gas<\/strong>: for the inspection of pipelines, reservoirs and drilling equipment.<br \/>\u2022 <strong>Power generation<\/strong>: for the inspection of turbines, generators and power plant components.<br \/>\u2022 <strong>Railways<\/strong>: inspection of axles, wheels and safety components.<\/p>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>CR Inspection, your partner for non-destructive testing<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; text_font=&#8221;||||||||&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p style=\"font-weight: 400;\"><strong>CR Inspection<\/strong>, through its <strong>certified organization distributed throughout the Italian territory<\/strong>, is the <strong>right and reliable partner<\/strong> for the <strong>execution<\/strong> of <a href=\"https:\/\/crinspection.it\/en\/ndt\/\"><strong>non-destructive tests<\/strong><\/a>. We offer <strong>punctual execution, complete assistance and transparency in costs<\/strong>. Our <strong>team of experienced technicians<\/strong> is <strong>certified<\/strong> and ready to offer <strong>customized solutions<\/strong> to meet your specific needs. In addition, as a <strong>certifying body<\/strong>, we not only carry out the checks, but <a href=\"https:\/\/crinspection.it\/en\/personnel-certification\/\"><strong>also certify the employees<\/strong><\/a>, using <strong>highly qualified technicians<\/strong> who are also <strong>teachers and examiners<\/strong>. This <strong>expertise<\/strong> not only guarantees <strong>compliance with the highest quality standards<\/strong>, but offers customers the <strong>security of relying on experienced professionals<\/strong> who are up-to-date on <strong>the methodologies and innovations in the sector<\/strong>.    <\/p>\n<p>To find out more, you can contact our <strong>service contact person, Niccol\u00f2<\/strong>, at <a href=\"tel:+393286949955\"><strong>328 6949955<\/strong><\/a> or email <a href=\"mailto:niccolo@crinspection.it\"><strong>niccolo@crinspection.it<\/strong><\/a>.<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.19.4&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Magnetoscopy, also known as magnetic particle testing (MT), is a non-destructive testing (NDT) method used to detect surface and sub-surface discontinuities in ferromagnetic materials. This method takes advantage of the magnetic properties of materials to identify defects such as cracks, inclusions, porosity, and other discontinuities that could compromise the structural integrity of a component. <\/p>\n","protected":false},"author":10,"featured_media":28362,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[52],"tags":[],"class_list":["post-30177","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-non-destructive-testing"],"_links":{"self":[{"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/posts\/30177","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/comments?post=30177"}],"version-history":[{"count":1,"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/posts\/30177\/revisions"}],"predecessor-version":[{"id":30180,"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/posts\/30177\/revisions\/30180"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/media\/28362"}],"wp:attachment":[{"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/media?parent=30177"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/categories?post=30177"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/crinspection.it\/en\/wp-json\/wp\/v2\/tags?post=30177"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}